Dante DLH4200B Especificações Página 1

Consulte online ou descarregue Especificações para Gateways/controladores Dante DLH4200B. Dante DLH4200B Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1

DLH4200B Matrix Switcher Installation and Operations Manual Model Number: DLH4200B Description: Enclosure Style

Página 2

10 INSTALLATION NOTE: There are no user-serviceable parts inside this unit. Only authorized service personnel may open the unit. Unpack

Página 3

11 AUDIO/VIDEO SOURCES NOTE: The end point of any video cable run must be terminated in 75 ohms. The DLH4200B SERIES offers 48 full-function audio

Página 4

12 2. Set the Video Inputs according to your system requirements. Figure 4. Connecting Terminated Video Sources Figu

Página 5

13 CONTROL LINES NOTE: D and P protocol receivers cannot be mixed on the same communication por

Página 6

14 MONITORS The DLH4200B SERIES supports 16 monitors. 1. Install monitors according to the instructions provided with them.

Página 7

15 CONNECTING A SINGLE RELAY INTERFACE UNIT To connect a single Relay Interface Unit: 1. Connect the Relay OUT port to COM 3 (Default Port

Página 8

16 ALARMS The DLH4200B SERIES provides numerous alarm handling options. Refer to the Programming section for a detailed description. 1. Co

Página 9

17 CONNECTING DEVICES THROUGH THE COMMUNICATION PORTS The DLH4200B SERIES Matrix Switcher/Controller provides 10 communication ports on th

Página 10 - MOUNTING

18 Table A. Communication Port Devices and Wiring Port Input Type Wiring Pin-Outs Default Device 1 DB9 RJ-45 RS-232 2 Rx 3 Tx 5 G

Página 11 - AUDIO/VIDEO SOURCES

19 Table B. Default Port Settings Port Default Settings 1 RS-232, 9600 baud, NO parity, 8 data bits, 1 stop bit 2 RS-232, 9600 baud, NO parity,

Página 12

TABLE OF CONTENTS IMPORTANT SAFEGUARDS AND WARNINGS ...

Página 13 - CONTROL LINES

20 KEYBOARDS You can connect up to 8 remotely connected keyboards to any of the following ports: • COM 5 (1 direct-powered keyboa

Página 14 - MONITORS

21 SYSTEM START-UP After completing the system installation, follow the procedure below to start proper system operation. Skip any “syste

Página 15

22 CONFIGURE THE SYSTEM The DLH4200B SERIES is shipped from the factory with default programming settings. If the defaults are acceptable, the D

Página 16 - ALARMS

23 PROGRAMMING THE DLH4200B SERIES NOTE: The DLH4200B SERIES allows system programming from only one monitor at a time. The DLH

Página 17 - 8 RJ

24 PROGRAMMING FROM THE KEYBOARDS Password - protected, on-screen programming screens accessible directly from the keyboards. 【【【【MAIN M

Página 18

25 DLH4200B SERIES PROGRAMMING MODE 1. If you have not already done so, select the monitor. 2. Press the PGM key. T

Página 19

26 EXIT PROGRAMMING MODE To return to active video you can:  Press the PGM key once while in the Main Menu.  Press the PGM key repeatedly

Página 20 - KEYBOARDS

27 CAMERA PROGRAMMING The DLH4200B SERIES supports the following ways to programming the camera: 1. LOCAL CAMERA:

Página 21 - POWER-UP THE SYSTEM

28 that has not already been assigned to a physical camera input. The logical number of the camera is unique and can’t duplicate in the whole networ

Página 22 - CONFIGURE THE SYSTEM

29 【NET CAMERA】Programming the parameter of the network camera. SER.NUM:Select the serial number of the network camera(1~256)。 LO

Página 23

WATCH ...43 ABOUT ...

Página 24

30 PORT PROGRAMMING Use the Port screen to configure the settings for each device connected to a Serial/COM port on the rear pane

Página 25

31 ALARM :Alarm inputs MAXPRO: the MAX1000 series matrix control port CM97SAT: PELCO-CM97XX Satellite port CM97DT : The PELCO-CM9700 or DLH4200

Página 26 - EXIT PROGRAMMING MODE

32 MONITOR PROGRAMMING ◇ Use the Monitor screen to adjust monitor display settings. PHY.NUM: Select the physical

Página 27 - CAMERA PROGRAMMING

33 PRIORITY The DLH4200B SERIES provides eight levels of priority control. Each level defines the ability of a keyboard to control a pan/tilt/zoom

Página 28

34 ALARM Configure any of the eight internal alarm inputs on the DLH4200B SERIES rear panel. Internal inputs are programmable to associate any ca

Página 29

35 will time out automatically after the interval specified in the DWL field. In the matrix, configure up to eight steps to be triggered as a resul

Página 30 - PORT PROGRAMMING

36 ACCESS The DLH4200B SERIES supports a way to restrict switching system access. Restrict a keyboard from calling selected cameras to monitors or

Página 31

37 SEQUENCE SEQUENCE: Select the sequence number you want to program. (01-08). Each sequence can include up to 64 steps. CAM:

Página 32 - MONITOR PROGRAMMING

38 DISPLAY Use the Monitor screen to adjust monitor display settings for your system. CAM TITLE: Enable (ON) or disabl

Página 33 - PRIORITY

39 TIME & DATE Use the Time and Date screen to set the system time and date settings. The system time and date information is kept current in

Página 34 - ALARM

Updated version of Manual with Manchester Control code………………..….74 Manchester Code Communication……………………………………………………………………………………..75 Control Descr

Página 35

40 PASSWORD Use the Set Password screen to change the system password. NOTICE: If you change the password and then forget the new one, you will

Página 36

41 SYSTEM Matrix network System: Two or more matrix systems, connected together via some setting rules and networking mode, so that con

Página 37 - SEQUENCE

42 ETHERNET IP ADDR: Establish IP address GATEWAY: Establish gateway address PORT: Establish number of

Página 38 - DISPLAY

43 WATCH Look into port data flow. You can pass this window way, understand the information of data flow of each port RX:

Página 39

44 ABOUT ABOUT DLH4200B SERIES MXB MODEL:DLH4200B SERIES Model CODE VER: Code version FONT VER: Font version NOTE: Desig

Página 40 - PASSWORD

45 OPERATING THE DLH4200B SERIES The DLH4200B SERIES can be operated with a keyboard.  INSTALL THE DLH4200B SERI

Página 41 - SYSTEM

46  PTZ CONTROL Select a suitable camera and operate a PTZ function. A keyboard with “view-only” access can view the signal from the specif

Página 42 - ETHERNET

47  OPERATE AUXILIARIES/RELAYS Two internal auxiliary outputs are provided on the back of the DLH4200B SERIES. They are relay outputs. You can

Página 43

48  OPERATE SEQUENCES SEQUENCES: Allows an operator to see a routine of camera views on any system monitor, repeatedly. The sequence can be

Página 44 - ABOUT

49 Access the programming menu, if screen appears like below after configuration, it completes the following steps: 1. camera 1 run pres

Página 45 -  CREATE AND RUN A PRESET

IMPORTANT SAFEGUARDS AND WARNINGS 1. Read, keep, and follow these instructions. 2. Heed all warnings. 3. There are no user-servicea

Página 46 -  CREATE AND RUN A PATTERN

50  ACKNOWLEDGE AN ALARM ◇ Alarm Display The DLH4200B SERIES can detect two types of alarm: internal alarm and external alarm. When an alar

Página 47 -  OPERATE AUXILIARIES/RELAYS

51  KEYBOARD OFF LINE DLH4200B SERIES can give a off line message for each working keyboard Pull connecting line or dump the power when a keyboar

Página 48 -  OPERATE SEQUENCES

52 MATRIX NETWORK SYSTEM Matrix network System: Two or more matrix systems, connected together via some setting rules and networking mode, so

Página 49

53 SYSTEM SETTING First, define each node (network node 1~255). Setup network link port of each Matrix on its prog

Página 50 -  ACKNOWLEDGE AN ALARM

54 LOG.NUM:Select the logical camera number of the network camera. (1-9999) NOTE: The logical number of the camera is unique and can’t duplicate in

Página 51 -  KEYBOARD OFF LINE

55 APPENDIX A DLH4200B SERIES MATRIX IS THE SATELLITE MATRIX OF THE PELCO SYSTEM MATRIX TO CONNECT THE SETUP LINK METHOD The DLH4200B SERIES m

Página 52

56 SYSTEM SETTING DLH4200B SERIES matrix parameter setup 1、Setup link port of DLH4200B SERIES Matrix on its programming menu.

Página 53 - SYSTEM SETTING

57 CM97XX matrix parameter setup PELCO satellite matrix connect the parameter setup contain two kinds of methods:A kind of setup through

Página 54

58 Figure 5:Select Device Type (3)After Select Device Type, click “Next” picking, flick “Port Configuration” setup window way open. (Refer to Fi

Página 55 - LINK METHOD

59 Figure7:Satellite Camera Assignment Select the number of satellite Select the physical number of the first

Página 56

6 DESCRIPTION DLH4200B SERIES Matrix Switcher/Controller is a cross-point Audio/video matrix switcher. The DLH4200B SERIES provides switchin

Página 57

60 (5)After satellite camera assignment, click “Next” picking, flick “Satellite Camera Logical Number” setup window way open. (Refer to F

Página 58

61 CONNECTING DEVICES THROUGH THE COMMUNICATION PORTS DLH4200B SERIES Matrix RJ45 Communication Port Inputs

Página 59

62 PELCO-CM97XX-CC1 RJ45 Communication Port Inputs

Página 60

63 APPENDIX B CONNECTING MV96e MULTIPLEXERS The DLH4200B SERIES can be use to link and control the MV96e series multiplexers, th

Página 61

64 OPERATING THE MV96e 1、 After establishing the connectivity completion, use the video cables "mon" port and the video matrix (the DLH4

Página 62

65 APPENDIX C The Ethernet Communication Module The Ethernet communication module provides the network data support for the matrix control, suppor

Página 63

66 10008 (Default Settings),port of the Ethernet, local port. MAC: Establish MAC address (The parameter can

Página 64

67 To save the revised parameters, first press “OK” and then press “Apply Settings”. 2.1 Ethernet parameters setup Set up the IP address, Subnet

Página 65

68 2.2 Ethernet Service Setup the password, port by WEB browse. Telnet/Http Password: Enter WEB or the Telnet password, the user name and the pa

Página 66

69 Monitor Mode @ Bootup: When system started, whether it allows entering the setup mode? If the setup is disabled, then the IP address of the Ether

Página 67

7 Keyboards Up to 16 keyboards can be connected to the DLH4200B SERIES. Camera positioning can be programmed and control

Página 68

70  UDP Protocol :UDP Datagram Type :01 Accept incoming:YES Local Port: 10008 Remote Port: 10008 Remote Host: 192.168.3.255 The loca

Página 69

71 3....DEVICE MANAGEMENT SOFTWARE This is as similar as the WEB management function, but the device management software may more conveni

Página 70

72 4. Data Station Monitor 4.1 Data Monitor Enter the Matrix program menu, select the item WATCH. If there’s any changes by value

Página 71

73 4.2 Status Monitor There are two LED outside the network module, and it may demonstrate the current network condition. Link LED Left Sid

Página 72

74 Updated version of Manual with Manchester Control Code version: 1.2.01 Update date: 8-6-2007 Data saving and loading In system menu list, data s

Página 73

75 Manchester code Communication The module support Manchester code Communication, and control the front end system, like tripo

Página 74

76 CONTROL DESCRIPTION Control operation contains: UP, DOWN, LEFT, RIGHT, aperture, focus and zoom adjust. Supports 1~72 presets; some presets

Página 75

77 TROUBLESHOOTING NOTE: There are no user-serviceable parts inside the DLH4200B SERIES. Only authorized service personnel may open the unit.

Página 76

78 character decimal format character decimal format < space > 32 G 71 0 48 H 72 1 49 I 73 2 50 J 74 3 51 K 75 4 52 L

Página 77 - TROUBLESHOOTING

79 SPECIFICATIONS GENERAL Keyboards: Sixteen Power of Keyboards: Two, Additional keyboards will require

Página 78

8 Alarm Inputs Eight internal alarm inputs are provided on the rear panel of the matrix switcher/controller. These internal alarm inputs

Página 79 - MECHANICAL

9 MODELS DLH4200B SERIES Matrix switcher/controller with up to 48 audio/video inputs

Comentários a estes Manuais